- Inotek Analysis Powered
Building Condition Reports
Comprehensive thermal surveys and detailed building assessments for facilities management and property maintenance.
Comprehensive Building Assessment Package
Our building condition reports combine advanced thermal scanning with detailed visual inspections to provide complete building health assessments.
Thermal Analysis
Advanced infrared imaging to detect heat loss, moisture ingress, and insulation defects with precise temperature mapping.
- Heat loss identification
- Moisture detection
- Insulation assessment
- HVAC efficiency analysis
Visual Inspection
High-resolution 4K photography and detailed visual assessment of building exteriors and structural elements.
- 4K aerial photography
- Structural defect detection
- Surface condition analysis
- Safety hazard identification
Detailed Reporting
Comprehensive reports with prioritized recommendations, cost estimates, and maintenance schedules.
- Priority-based recommendations
- Cost estimation guidance
- Maintenance scheduling
- Compliance documentation
- Exclusive UK Partnership
Powered by Inotek Analysis
We're the exclusive UK partner for Inotek Analysis, bringing you industry-leading building condition assessment technology.
Advanced Analytics
Predictive maintenance insights and data-driven recommendations
Industry Benchmarking
Compare your building performance against industry standards
System Integration
Seamless integration with existing facilities management systems
Compliance Tracking
Automated compliance monitoring and regulatory reporting
Our Assessment Process
From initial consultation to final report delivery, our streamlined process ensures comprehensive building assessments.
Initial Consultation
Discussion of requirements, site access, and assessment scope
Drone Survey
Comprehensive thermal and visual inspection using advanced drone technology
Data Analysis
Inotek Analysis processing and expert assessment of collected data
Report Delivery
Detailed condition report with prioritized recommendations
Survey: 1-2 Days
On-site data collection
Analysis: 3-5 Days
Data processing & report creation
Delivery: 7-10 Days
Complete report with recommendations
Example Building Condition Report Findings


Deviation 001 – Roof
Roof • RPL 3
Heat loss has been identified in the marked thermogram, indicating a thermal anomaly in the roof
section. This suggests the presence of a thermal bridge, where heat is escaping through areas of
insufficient insulation. The observable evidence from the thermogram highlights the specific locations
where the temperature differential is significant. The extent of the issue appears to be localized, but it
may have implications for overall energy efficiency and comfort within the building. The affected areas
should be closely monitored for further signs of heat loss or moisture intrusion. Visual inspection may
reveal additional clues regarding the integrity of the insulation in these regions.


Deviation 002 – Roof
Roof • RPL 3
Significant moisture accumulation has been detected beneath the roofing membrane, as evidenced by
the attached thermal image. The affected area is located on the roof, where the insulation is likely
compromised due to the presence of water. This condition poses a risk of further damage to the roofing
structure and insulation materials. The extent of the moisture accumulation suggests a prolonged
exposure to water, which could lead to mold growth and deterioration of building materials. Immediate
attention is required to assess the full impact of this moisture intrusion.


Deviation 005 – Facade
Facade • RPL 3
Cracking has been observed in the facade, which is evident both thermally and visually. The cracks appear to be distributed across various sections of the facade, indicating a potential structural issue. The extent of the cracking suggests that it may be significant, warranting further investigation. The visual evidence shows irregular patterns of cracking that could compromise the integrity of the building.
Thermal imaging may reveal temperature differentials associated with the cracks, suggesting underlying issues. The facade’s condition raises concerns about its long-term durability and performance.


Deviation 007 – Facade
Facade • RPL 3
Significant moisture retention has been observed in the construction, which is evident as darker areas in the attached thermal image. This moisture issue appears to be widespread, affecting various sections of the facade. The extent of the moisture infiltration suggests a potential underlying problem that requires further investigation. The affected areas are likely to compromise the integrity of the building materials and may lead to further deterioration if not addressed promptly. The presence of moisture can also create an environment conducive to mold growth, posing health risks to occupants. A thorough assessment is necessary to determine the full extent of the damage and the specific locations impacted.


Deviation 008 – Facade
Facade • RPL 2
The marked window exhibits clear signs of puncturing, which is visible upon inspection. This defect is characterized by the presence of air leakage between the glass layers, leading to a compromised thermal performance of the window. The issue is localized to the specific window indicated, and it affects the overall energy efficiency of the facade. The visual evidence suggests that the integrity of the window’s seal has been breached, which may also lead to condensation or fogging between the panes. This condition can significantly impact the comfort and energy consumption of the building. The extent of the problem appears to be limited to this particular window, but it may indicate broader issues if not addressed promptly.
Why Choose Our Building Condition Reports
Professional assessments that help facilities managers make informed maintenance decisions and optimize building performance.
Cost Savings
Early detection of issues prevents costly emergency repairs and extends building lifespan.
Compliance Support
Professional reports support regulatory compliance and insurance requirements.
Enhanced Safety
Drone technology eliminates the need for dangerous manual inspections at height.
Maintenance Planning
Prioritized recommendations help plan and budget for future maintenance needs.
Energy Efficiency
Thermal imaging identifies energy loss areas, helping reduce operational costs.
Detailed Documentation
Comprehensive visual and thermal records for asset management and historical tracking.
Ready for Your Building Condition Assessment?
Get a comprehensive thermal survey and detailed condition report. Our expert team is ready to help optimize your building performance.